Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Braz. j. oral sci ; 17: e18138, 2018. tab
Article in English | LILACS, BBO | ID: biblio-963962

ABSTRACT

Aim: The objective of this study was to compare the efficiencies of different adhesive systems used to bond orthodontic brackets as well as the fracture pattern during debonding on bovine teeth. Methods: The sample included 45 specimens assigned to 3 groups according to the adhesive system applied: Group I: Transbond XT (3M Unitek®, Monrovia/CA -USA), Group II: Orthocem (FGM® Joinville/SC-BR), and Group III: Orthobond (Morelli®, Sorocaba/SP-BR). For this purpose, metal brackets were bonded to bovine teeth following the instructions from each manufacturer. The specimens were subjected to a shear test to assess bond strength (BS). Finally, after debonding, the adhesive remnant index (ARI) was estimated. Results: The average shear strength for a tooth bonded using the adhesive system Transbond XT was 16.39 MPa, while it was 18.08 Mpa for Orthocem and 7.28 Mpa for Orthobond; The Tukey test revealed no statistically significant differences between groups I and II (p < 0.01) and group III differed statistically from groups I and II. Conclusion: In conclusion, both adhesive systems Transbond XT and Orthocem attained higher bond strength values than Orthobond; the fracture pattern was similar for all adhesive systems applied


Subject(s)
Animals , Cattle , Dental Bonding , Orthodontic Brackets , Dental Enamel , Shear Strength
2.
Braz. j. oral sci ; 14(3): 251-255, July-Sept. 2015. tab, graf
Article in English | LILACS, BBO | ID: lil-770531

ABSTRACT

Abstract Aim : To assess the surface topography and chemical composition of three brands of as-received mini-implants (SIN(r), Morelli(r), and Conexao(r)). Methods: Twelve mini-implants of each brand were analyzed by scanning electron microscopy and energy dispersive X-ray (EDX). Results: There was no significant differences among SIN(r), Morelli(r), and Conexao(r) mini-implants comparing their surface topography by visualization of SEM micrographs and analysis of scores. The EDX analysis showed statistically significant difference among them for the amount of Ti, Al and V. Miniimplants SIN(r)presented also N and O in their composition. Conclusions: In conclusion, the miniimplants Morelli(r), SIN(r) and Conexao(r) presented Ti as main component of the alloy. Remaining components, such as Al and V, were also observed in all the analyzed brands, with differences among them. Only SIN(r)mini-implants presented N and O. As far as surface topography is concerned, there are no differences among the three brands of mini-implants.


Subject(s)
Orthodontics , Titanium , Orthodontic Anchorage Procedures
3.
Ortodontia ; 48(5): 411-419, set.-out.2015. ilus
Article in Portuguese | LILACS | ID: lil-783992

ABSTRACT

Embora incomum, a impacção de incisivos centrais superiores é geralmente diagnosticada precocemente, devido à importância destes dentes na função mastigatória e na aparência do indivíduo. O objetivo deste trabalho foi relatar dois casos clínicos nos quais uma abordagem cirúrgica e ortodôntica foi realizada para tratar incisivos centrais impactados. Em ambos os casos, foi realizada a expansão rápida da maxila com o auxílio de um aparelho disjuntor de Haas. Da mesma forma, foi efetuada a exposição cirúrgica e o tracionamento ortodôntico do incisivo central superior impactado. Forças ortodônticas leves foram utilizadas durante todo o tracionamento ortodôntico, as quais foram aplicadas em arcos rígidos. Ao final do tratamento, os dentes apresentavam uma altura de coroa clínica adequada, contornos gengivais satisfatórios e vitalidade pulpar. De acordo com o desfecho clínico dos dois casos apresentados, pôde-se concluir que a exposição cirúrgica bem planejada, associada ao tracionamento ortodôntico dos dentes impactados contribuiu para os resultados positivos observados neste estudo...


Although uncommon, the impaction of maxillary central incisors is usually early diagnosed, due to the importance of these teeth in masticatory function and appearance of the individual. The aim of this paper was to report two clinical cases, in which surgical and orthodontic approach were performed, in order to treat impacted central incisors. In both cases, we have done the rapid disjunction of the midpalatal suture, as well as exposure and orthodontic traction of the impacted maxillary central incisor. Light forces were used during the all the orthodontic traction, which were applied on rigid archs. It was noted that the teeth presented adequate clinical crown height, satisfactory gingival contours and pulp vitality. It can be concluded that a well-planned surgical exposure of the impacted teeth in association with orthodontic traction contributed to periodontal and aesthetic optimal treatment outcomes...


Subject(s)
Humans , Male , Child , Incisor/surgery , Orthodontics, Corrective , Tooth, Impacted
4.
Braz. oral res. (Online) ; 29(1): 1-8, 2015. tab, ilus
Article in English | LILACS | ID: lil-777219

ABSTRACT

This study aims at comparing conventional and nickel-free metal bracket surface characteristics with elemental composition by scanning electron microscopy (SEM), using energy dispersive spectroscopy (EDS). The sample consisted of 40 lower incisor brackets divided into four groups: ABZ = conventional brackets, Kirium Abzil 3M® (n = 10); RL = conventional brackets, Roth Light Morelli® (n = 10); NF = nickel-free brackets, Nickel-Free Morelli® (n = 10); and RM = nickel-free brackets, Roth Max Morelli® (n = 10). Qualitative evaluation of the bracket surface was performed using SEM, whereby surface features were described and compared. The elemental composition was analyzed by EDS. According to surface analysis,groups ABZ and RL showed a homogeneous surface, with better finishing, whereas the surfaces in groups NF and RM were rougher. The chemical components with the highest percentage were Fe, Cr and C. Groups NF and MR showed no nickel in their composition. In conclusion, the bracket surface of the ABZ and RL groups was more homogeneous, with grooves and pores, whereas the surfaces in groups NF and RM showed numerous flaws, cracks, pores and grooves. The chemical composition analysis confirmed that the nickel-free brackets had no Ni in their composition, as confirmed by the manufacturer’s specifications, and were therefore safe to use in patients with a medical history of allergy to this metal.


Subject(s)
Metals/chemistry , Nickel/chemistry , Orthodontic Brackets , Analysis of Variance , Alloys/chemistry , Corrosion , Materials Testing , Microscopy, Electron, Scanning , Reference Values , Spectrometry, X-Ray Emission , Statistics, Nonparametric , Surface Properties
5.
Ortodontia ; 47(4): 353-361, jul.-ago.2014. ilus
Article in Portuguese | LILACS | ID: lil-760054

ABSTRACT

O aumento do interesse por parte dos adultos em tratamentos ortodônticos tem levado as empresas a desenvolverem novas alternativas que utilizem aparelhos ortodônticos menos perceptíveis e mais estéticos. Os alinhadores estéticos destacam-se entre as opções de tratamento que atendem a estas expectativas. Serão apresentados neste trabalho alguns aspectos relevantes sobre estes dispositivos, além de dois casos clínicos tratados com o sistema Essix MTM (Dentsply), em que todos os objetivos estéticos e funcionais propostos foram alcançados. Os resultados encontrados neste trabalho corroboram com a ideia de que, quando bem indicados, os alinhadores estéticos são uma opção viável de tratamento dentro do cotidiano clínico do ortodontista...


The increased interest in orthodontics by adults has led companies to develop new treatment alternatives that use less visible and more aesthetic orthodontic appliances. The aesthetic aligners stand out among the treatment options that attend these expectations. This paper presented some relevant aspects of these devices, as well as two cases treated with Essix MTM (Dentsply) system, in which all aesthetic and functional objectives proposed treatment have been achieved. The results of this study support the idea that, when properly indicated, aesthetic aligners are a viable treatment option within the clinical routine of the orthodontist...


Subject(s)
Humans , Male , Adolescent , Middle Aged , Esthetics, Dental , Tooth Movement Techniques , Orthodontic Appliances, Removable
6.
Dental press j. orthod. (Impr.) ; 17(6): 20e1-20e5, Nov.-Dec. 2012. ilus
Article in English | LILACS | ID: lil-669385

ABSTRACT

INTRODUCTION: Tooth movement is initially characterized by an acute sterile inflammation, followed by sequential multiple reactions in the periodontal ligament in response to biomechanical forces. Pharmacological agents such as corticosteroids may affect the course of orthodontic movement. Scientific studies show antagonistic actions of these drugs on bone resorption during tooth movement. OBJECTIVE: To review the literature about the effect of corticosteroids on orthodontic tooth movement. CONCLUSION: Patients should be questioned regarding the use of these drugs in the orthodontic practice and for those who use them, the orthodontic treatment should be differentiated, with longer intervals between visits and periodic X-rays due to the delay in bone formation observed in some scientific studies.


INTRODUÇÃO: a movimentação dentária é caracterizada, inicialmente, por uma inflamação aguda estéril, seguida por reações múltiplas sequenciais no ligamento periodontal em resposta às forças biomecânicas. Agentes farmacológicos, como os corticosteroides, podem alterar o curso da movimentação ortodôntica. Os estudos científicos demonstram ações antagonistas dessas drogas sobre a reabsorção óssea durante a movimentação dentária. OBJETIVO: realizar revisão de literatura sobre a ação dos corticosteroides no movimento dentário ortodôntico. CONCLUSÃO: os pacientes devem ser questionados quanto ao uso dessas drogas na clínica ortodôntica e, para aqueles que fazem uso, o tratamento ortodôntico deve ser diferenciado, com intervalos maiores entre as consultas e solicitação periódica de radiografias devido ao atraso na neoformação óssea observado em alguns estudos científicos.

7.
Rev. dent. press ortodon. ortopedi. facial ; 14(4): 83-91, jul.-ago. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-520198

ABSTRACT

INTRODUÇÃO: a hipertrofia de adenoide é uma das principais causas da respiração bucal. Entre os métodos utilizados para o diagnóstico dessa condição, os mais precisos são a endoscopia nasal e a ressonância magnética. No entanto, o método mais utilizado, em Odontologia, é a radiografia cefalométrica lateral. OBJETIVO: determinar a eficácia dessa radiografia no diagnóstico da hipertrofia de adenoide, pela sua comparação com a endoscopia nasal. MÉTODOS: foram avaliados 30 indivíduos (7 a 12 anos). Todos fizeram exame de endoscopia nasal e radiografia cefalométrica lateral. Nas endoscopias, foi registrada a porcentagem de obstrução da nasofaringe e, nas radiografias, a menor dimensão anteroposterior livre da nasofaringe. RESULTADOS: os exames se mostraram fortemente correlacionados (r = - 0,793, p-valor < 0,01). Considerou-se portadores de hipertrofia severa de adenoide os pacientes que apresentaram, na endoscopia, obstrução da nasofaringe igual ou superior a 75 por cento e, nas radiografias, o menor diâmetro anteroposterior da nasofaringe igual ou inferior a 5mm; o exame radiográfico teve uma sensibilidade de 75 por cento, especificidade de 86,3 por cento, valor preditivo positivo de 66,7 por cento, valor preditivo negativo de 90,4 por cento e exatidão de 83,3 por cento. CONCLUSÃO: a radiografia cefalométrica lateral se mostrou um exame eficiente para o diagnóstico da hipertrofia de adenoide.


INTRODUCTION: One of the most usual causes of mouth breathing is adenoids hypertrophy with reduction of the nasopharyngeal space. The most precise diagnostic methods are magnetic resonance and nasal endoscopy, because they make possible a three dimension image of the nasopharynx. However, in Dentistry, cephalometric radiography is the method used in the majority of cases. That is why it is so important the evaluation of the efficacy of this diagnostic method. AIM: The aim of this paper is to determine the efficacy of the lateral cephalometric radiography in diagnosing adenoids hypertrophy, comparing this method to the nasal endoscopy. METHODS: Thirty patients (7 to 12 years), with no history of otolaryngological surgery, were evaluated. All of them were submitted to a nasal endoscopy and a lateral cephalometric radiography. In the endoscopic exams it was registered the percentage of nasopharyngeal obstruction and in the radiographic exams it was registered the minor nasopharyngeal dimension. RESULTS: The results of the exams showed a strong correlation with each other (r = - 0.793, p-value < 0.01). After that, reliability tests to the radiographic diagnose were performed, assuming that 75 percent (endoscopic exams) and 5mm (radiographic exams) were the limit values to the determination of the diagnose of severe adenoids hypertrophy. The radiographic exam showed a sensibility of 75 percent, specificity of 86.3 percent, positive predictive value of 66.7 percent, negative predictive value of 90.4 percent and an exactness of 83.3 percent. Therefore, lateral cephalometric radiography is an efficient method of adenoids hypertrophy diagnose. It was proved by the strong correlation of its results with the results of the nasal endoscopy, that is considered a method of excellence for diagnosing this condition.


Subject(s)
Humans , Male , Female , Child , Adenoids , Cephalometry , Radiography , Endoscopy , Mouth Breathing
8.
Rev. dent. press ortodon. ortopedi. facial ; 12(1): 33-40, jan.-fev. 2007.
Article in Portuguese | LILACS | ID: lil-443826

ABSTRACT

INTRODUÇÃO: existe um grande interesse no desenvolvimento de técnicas para a manipulação de células-tronco, no intuito de instituirem-se tratamentos restauradores de tecidos e órgãos. Para que a bioengenharia seja eficaz, faz-se necessária a presença de três fatores: as próprias células-tronco, uma matriz extracelular e fatores de crescimento. Existem inúmeros fatores de crescimento envolvidos no desenvolvimento do órgão dentário. Por isso pesquisadores ainda não foram capazes de formar um órgão completo, embora existam diversos estudos evidenciando a formação de esmalte e dentina a partir de células-tronco isoladas da polpa dentária. Recentemente, também foram isoladas células-tronco da polpa dos dentes decíduos. Sabe-se que estas células são altamente proliferativas, sendo de grande importância para o cirurgião-dentista o conhecimento do seu comportamento biológico e técnicas de obtenção. OBJETIVO: este estudo teve como objetivo realizar uma revisão de literatura acerca das atuais tendências das pesquisas com células-tronco na Odontologia, além de discorrer sobre os fatores implicados para o sucesso na utilização prática dessas células.


INTRODUCTION: there is great interest in developing techniques for manipulation of stem cells for the use in restoring organs and tissues. The effectiveness of bioengineering is based on the existence of stem cells, an extra cellular matrix and growth factors. Innumerous growth factors are involved in the development of dental organs, and this complexity of factors makes it extremely difficult to grow a complete organ, even though there are multiple essays reporting the formation of enamel and dentin from isolated stem cell, originating from dental pulp tissues. More recently, deciduous teeth have been used to extract stem cells from their pulp tissues. We know that these cells are highly proliferate. The recognition of the biological behavior of these cells and techniques used to isolate them is of great interest to dentists. AIM: the aim of this study was to review the current trends of research with stem cells in Dentistry and the factors implied for their practical and successful use.


Subject(s)
Humans , Biomedical Engineering , Dentistry/trends , Stem Cells
SELECTION OF CITATIONS
SEARCH DETAIL